Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 1333887007

Production
The component that hold information about this concept.
Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)
Fluoroscopy guided cutting balloon dilation of bilateral bronchi
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)

SCTID: 1333887007, Defined, Active


1333887007|Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)|
  • en Cutting balloon dilatation of both bronchi using fluoroscopic guidance
  • en Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance
  • en Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)
  • en Fluoroscopy guided cutting balloon dilatation of bilateral bronchi
  • en Fluoroscopy guided cutting balloon dilation of bilateral bronchi

1333887007 |Cutting balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)|

=== 1147151000000103 |Balloon dilation of bilateral bronchi using fluoroscopic guidance (procedure)| +
    1333885004 |Cutting balloon dilation of left bronchus using fluoroscopic guidance (procedure)| +
    1333886003 |Cutting balloon dilation of right bronchus using fluoroscopic guidance (procedure)| :
        { 260686004 |Method (attribute)| = 129419002 |Dilation - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 736637009 |Structure of left bronchus (body structure)|,
          424226004 |Using device (attribute)| = 303779005 |Balloon dilatation catheter (physical object)| }
        { 260686004 |Method (attribute)| = 129419002 |Dilation - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 736638004 |Structure of right bronchus (body structure)|,
          424226004 |Using device (attribute)| = 303779005 |Balloon dilatation catheter (physical object)| }
        { 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 736637009 |Structure of left bronchus (body structure)| }
        { 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 736638004 |Structure of right bronchus (body structure)| }
Active
esc