Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 1333912009

Production
The component that hold information about this concept.
Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance (procedure)
Fluoroscopy guided application of external fixator on bone of bilateral upper limbs
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance (procedure)

SCTID: 1333912009, Defined, Active


1333912009|Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance (procedure)|
  • en Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance
  • en Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance (procedure)
  • en Application of external fixator on bone of both upper limbs using fluoroscopic guidance
  • en Fluoroscopy guided application of external fixator on bone of bilateral upper limbs

1333912009 |Application of external fixator on bone of bilateral upper limbs using fluoroscopic guidance (procedure)|

=== 561000087104 |Fluoroscopy of bilateral upper limbs (procedure)| +
    1333911002 |Application of external fixator on bone of right upper limb using fluoroscopic guidance (procedure)| +
    1333910001 |Application of external fixator on bone of left upper limb using fluoroscopic guidance (procedure)| :
        { 363699004 |Direct device (attribute)| = 261200006 |External fixation system (physical object)|,
          260686004 |Method (attribute)| = 129425003 |Application - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 719309000 |Bone structure of left upper limb (body structure)| }
        { 363699004 |Direct device (attribute)| = 261200006 |External fixation system (physical object)|,
          260686004 |Method (attribute)| = 129425003 |Application - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 719459008 |Bone structure of right upper limb (body structure)| }
        { 363699004 |Direct device (attribute)| = 261200006 |External fixation system (physical object)|,
          363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 719309000 |Bone structure of left upper limb (body structure)| }
        { 363699004 |Direct device (attribute)| = 261200006 |External fixation system (physical object)|,
          363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 719459008 |Bone structure of right upper limb (body structure)| }
Active
esc