Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 175237009

Production
The component that hold information about this concept.
Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis (procedure)
Tạo shunt từ động mạch dưới đòn phải đến động mạch phổi phải sử dụng thiết bị ống xen giữa
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis (procedure)

SCTID: 175237009, Primitive, Active


175237009|Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis (procedure)|
  • vi Tạo shunt từ động mạch dưới đòn phải đến động mạch phổi phải sử dụng thiết bị ống xen giữa
  • en Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis
  • en Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis (procedure)

175237009 |Creation of shunt from right subclavian artery to right pulmonary artery using interposition tube prosthesis (procedure)|

<<< 175236000 |Creation of shunt from subclavian artery to pulmonary artery using interposition tube prosthesis (procedure)| +
    447958003 |Creation of anastomosis from right subclavian artery to right pulmonary artery (procedure)| :
        { 260686004 |Method (attribute)| = 424208002 |Shunt - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 29700009 |Structure of right subclavian artery (body structure)|,
          424226004 |Using device (attribute)| = 272235006 |Interposition shunt (physical object)| }
        { 260686004 |Method (attribute)| = 424208002 |Shunt - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 78480002 |Structure of right pulmonary artery (body structure)|,
          424226004 |Using device (attribute)| = 272235006 |Interposition shunt (physical object)| }
        { 260686004 |Method (attribute)| = 424208002 |Shunt - action (qualifier value)|,
          405814001 |Procedure site - indirect (attribute)| = 128260003 |Pulmonary artery within lung (body structure)|,
          424226004 |Using device (attribute)| = 257351008 |Shunt (physical object)| }
        { 260686004 |Method (attribute)| = 257750007 |Side-to-side anastomosis (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 36765005 |Structure of subclavian artery (body structure)| }
        { 260686004 |Method (attribute)| = 257750007 |Side-to-side anastomosis (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 81040000 |Pulmonary artery structure (body structure)| }
        { 260686004 |Method (attribute)| = 257741005 |Anastomosis - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 363574006 |Intrathoracic arterial structure (body structure)| }
Active
esc