Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 179118004

Production
  • Language with ID “787f5ffb-fbb3-59b4-891c-6e713b0ba46e” doesn’t exist. Perhaps it was deleted?
The component that hold information about this concept.
Primary closed reduction of fracture and internal fixation with screw(s) (procedure)
Primary closed reduction of fracture and internal fixation with screw(s)
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Primary closed reduction of fracture and internal fixation with screw(s) (procedure)

SCTID: 179118004, Defined, Active


179118004|Primary closed reduction of fracture and internal fixation with screw(s) (procedure)|
  • en Primary closed reduction of fracture and internal fixation with screw(s)
  • en Primary closed reduction of fracture and internal fixation with screw(s) (procedure)

179118004 |Primary closed reduction of fracture and internal fixation with screw(s) (procedure)|

=== 311427005 |Primary closed reduction and internal fixation of fracture (procedure)| +
    239283000 |Fixation of fracture using screws (procedure)| :
        { 363700003 |Direct morphology (attribute)| = 72704001 |Fracture (morphologic abnormality)|,
          260686004 |Method (attribute)| = 129371009 |Fixation - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 272673000 |Bone structure (body structure)|,
          424226004 |Using device (attribute)| = 68183006 |Bone screw, device (physical object)| }
        { 363700003 |Direct morphology (attribute)| = 72704001 |Fracture (morphologic abnormality)|,
          260686004 |Method (attribute)| = 426413004 |Closed reduction - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 272673000 |Bone structure (body structure)|,
          246513007 |Revision status (attribute)| = 261424001 |Primary operation (qualifier value)| }
        { 363700003 |Direct morphology (attribute)| = 72704001 |Fracture (morphologic abnormality)|,
          260686004 |Method (attribute)| = 129371009 |Fixation - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 272673000 |Bone structure (body structure)|,
          246513007 |Revision status (attribute)| = 261424001 |Primary operation (qualifier value)|,
          424226004 |Using device (attribute)| = 31031000 |Orthopedic internal fixation system, device (physical object)| }
Active
esc