Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast (procedure)
Đặt stent kim loại  mở rộng vào đường mật ngược dòng qua nội soi
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast (procedure)

SCTID: 425503000, Primitive, Active


425503000|Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast (procedure)|
  • vi Đặt stent kim loại  mở rộng vào đường mật ngược dòng qua nội soi
  • en Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct
  • en Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast
  • en Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast (procedure)
  • en Ercp (endoscopic retrograde cholangiopancreatography) with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast

425503000 |Endoscopic retrograde cholangiopancreatography with insertion of covered metal stent into bile duct using fluoroscopic guidance with contrast (procedure)|

<<< 709197008 |Endoscopic insertion of stent into bile duct (procedure)| +
    431398002 |Insertion using fluoroscopic guidance (procedure)| +
    386722005 |Endoscopic retrograde cholangiography (procedure)| :
        { 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          116688005 |Procedure approach (attribute)| = 260526008 |Retrograde approach (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 28273000 |Bile duct structure (body structure)|,
          424361007 |Using substance (attribute)| = 385420005 |Contrast media (substance)| }
        { 260686004 |Method (attribute)| = 129433002 |Inspection - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 67109009 |Structure of ampulla of vater (body structure)|,
          424226004 |Using device (attribute)| = 705514000 |Duodenoscope (physical object)| }
        { 363699004 |Direct device (attribute)| = 360123005 |Biliary stent (physical object)|,
          260686004 |Method (attribute)| = 425362007 |Surgical insertion - action (qualifier value)|,
          405814001 |Procedure site - indirect (attribute)| = 28273000 |Bile duct structure (body structure)|,
          425391005 |Using access device (attribute)| = 705514000 |Duodenoscope (physical object)| }