Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 444889008

Production
The component that hold information about this concept.
Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant (procedure)
Cranial cruciate repair using tightrope procedure
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant (procedure)

SCTID: 444889008, Primitive, Active


444889008|Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant (procedure)|
  • en Cranial cruciate repair using tightrope procedure
  • en Extracapsular repair of tear of anterior cruciate ligament using suture stabilisation and fibre tape implant
  • en Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant
  • en Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant (procedure)

444889008 |Extracapsular repair of tear of anterior cruciate ligament using suture stabilization and fiber tape implant (procedure)|

<<< 281818006 |Stabilization of joint by ligament repair (procedure)| +
    239426007 |Repair of anterior cruciate ligament of knee joint (procedure)| +
    265205006 |Prosthetic repair of ligament (procedure)| :
        { 260686004 |Method (attribute)| = 129378003 |Stabilization - action (qualifier value)|,
          116688005 |Procedure approach (attribute)| = 360139003 |Extracapsular approach (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 895007 |Structure of anterior cruciate ligament of knee joint (body structure)|,
          424226004 |Using device (attribute)| = 27065002 |Surgical suture, device (physical object)| }
        { 363700003 |Direct morphology (attribute)| = 107658001 |Mechanical abnormality (morphologic abnormality)|,
          260686004 |Method (attribute)| = 257903006 |Repair - action (qualifier value)|,
          116688005 |Procedure approach (attribute)| = 360139003 |Extracapsular approach (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 895007 |Structure of anterior cruciate ligament of knee joint (body structure)|,
          424226004 |Using device (attribute)| = 14789005 |Prosthetic implant, device (physical object)| }
Active