Loading...
dock_to_right dock_to_right arrow_back

Terminology chevron_right Concepts chevron_right 609154002

Production
The component that hold information about this concept.
Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance (procedure)
Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance
Specifies if the concept version is primitive or defined. Set to a descendant of 900000000000444006

Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance (procedure)

SCTID: 609154002, Defined, Active


609154002|Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance (procedure)|
  • en Endovascular insertion of metal stent into coronary artery using fluoroscopic guidance with contrast
  • en Percutaneous transluminal insertion of metallic stent into coronary artery using fluoroscopic guidance with contrast
  • en Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance with contrast
  • en Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance with contrast (procedure)

609154002 |Percutaneous transluminal insertion of metal stent into coronary artery using fluoroscopic guidance (procedure)|

=== 36969009 |Placement of stent in coronary artery (procedure)| +
    415070008 |Percutaneous transarterial imaging guided coronary arterial intervention with contrast (procedure)| +
    704044002 |Endovascular insertion of metal stent (procedure)| +
    433594009 |Insertion of metallic stent using fluoroscopic guidance (procedure)| +
    703106001 |Vascular stent procedure using fluoroscopic guidance (procedure)| +
    429809004 |Fluoroscopic percutaneous transluminal angioplasty of coronary artery (procedure)| +
    709019007 |Percutaneous transluminal arterial angioplasty with insertion of stent (procedure)| :
        { 260507000 |Access (attribute)| = 103388001 |Percutaneous approach - access (qualifier value)|,
          260686004 |Method (attribute)| = 410817004 |Dilation repair - action (qualifier value)|,
          116688005 |Procedure approach (attribute)| = 261449002 |Transluminal approach (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 41801008 |Coronary artery structure (body structure)|,
          424226004 |Using device (attribute)| = 705928000 |Coronary angioplasty catheter (physical object)| }
        { 363699004 |Direct device (attribute)| = 1237098007 |Metal arterial stent (physical object)|,
          363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,
          260686004 |Method (attribute)| = 312275004 |Fluoroscopic imaging - action (qualifier value)|,
          405813007 |Procedure site - direct (attribute)| = 41801008 |Coronary artery structure (body structure)|,
          424361007 |Using substance (attribute)| = 385420005 |Contrast media (substance)| }
        { 260507000 |Access (attribute)| = 103388001 |Percutaneous approach - access (qualifier value)|,
          363699004 |Direct device (attribute)| = 1237098007 |Metal arterial stent (physical object)|,
          260686004 |Method (attribute)| = 425362007 |Surgical insertion - action (qualifier value)|,
          116688005 |Procedure approach (attribute)| = 261449002 |Transluminal approach (qualifier value)|,
          405814001 |Procedure site - indirect (attribute)| = 41801008 |Coronary artery structure (body structure)| }
Active